As you face the Fleck SXT control from the front, the water enters on the right and exits on the left. From the back (see Fig 2) the water enters on the left. The inlet and outlet are attached to the bypass valve which is marked with arrows as well. 3. Make sure there is a working gate or ball valve before the Fleck SXT Air Charger. Fleck Manuals Water Softeners Control Heads Set Up and Repair Instructions. Control Valve Time Clock Service Manual. , , Control Valve Manual Service Manual. Control Valve Econominder Service Manual. Control Valve Service Manual. FLECK Control Valve Service Manual • 3 OPERATING PARAMETERS Minimum Pressure 20 psi/ bar/ kPa Maximum Pressure psi/ bar/ kPa Minimum Water Temperature 34°F/1°C Maximum Water Temperature °F/65°C Maximum Humidity 75% IMPORTANT PLEASE READ: • The information, specifications and illustrations in this manual are.
Fleck Flow Meter Size: Paddle: 1" " 2" 3" Turbine: 1" " See P4 remote inputs in the wiring diagrams in the service manual. Regeneration Day Override Feature If the Day Override option is turned on and the valve reaches the set Regeneration Day Override value, the. 2. Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating the 24 hour dial until each screw appears in the cut out portion of the manual regeneration knob. 3. Loosen each screw slightly to release the pressure on the time plate from the 24 hour gear. 4. Locate the regeneration time pointer on the. Installer manual Fleck SXT - Generalities Ref. MKT-IM / E - 7 / Intended use The device is intended for commercial applications use only and it is purpose-built for water treatment. Abbreviations used Assy Assembly BLFC Brine Line Flow Controller BV Brine Valve CW Cold Water DF Down Flow Distr Distribution.
FLECK S Service Manual • 5 5. In any event, conditioned water may be drawn after rinse water stops flowing from the water conditioner drain line. How to Adjust Regeneration Time 1. Disconnect the power source. 2. Locate the three screws behind the manual regeneration knob by pushing the red button in and rotating the 24 hour. 4 • FLECK Downflow Service Manual START-UP INSTRUCTIONS The water softener should be installed with the inlet, outlet, and drain connections made in accordance with the manufacturer’s recommendations, and to meet applicable plumbing codes. 1. Turn the manual regeneraton knob slowly in a clockwise. Printed in U.S.A. Page 4 MODEL Hard water enters unit at valve inlet and flows down thru the mineral in the mineral tank. Conditioned water enters center tube thru the bottom distributor — then flows up thru the.
0コメント